Machine learning techniques for accelerating Monte Carlo simulations in radiotherapy and optimizing treatment planning
| dc.contributor.advisor | Tsiknakis, Emmanouil | en |
| dc.contributor.advisor | Nikiforaki, Aikaterini | en |
| dc.contributor.advisor | Marias, Konstantinos | en |
| dc.contributor.advisor | Τσικνάκης, Εμμανουήλ | el |
| dc.contributor.advisor | Νικηφοράκη, Αικατερίνη | el |
| dc.contributor.advisor | Μαριάς, Κονσταντίνος | el |
| dc.contributor.author | Salonikiou, Konstantinos | en |
| dc.contributor.author | Σαλονικιού, Κωνσταντίνος | el |
| dc.date.accessioned | 2026-11-23T12:51:47Z | |
| dc.date.available | 2026-11-23T12:51:47Z | |
| dc.date.issued | 2026-11-23 | |
| dc.description.abstract | This thesis presents a comprehensive framework for accelerated radiotherapy dose prediction and inverse treatment plan optimization, establishing a novel paradigm that bridge deter- ministic radiation transport physics with modern deep learning architectures In contrast to other methods in the literature that correlate masks (PTV, OAR contours) with dose distributions by abstraction of anatomical segmentation without taking into account the ac- tual beam physics, the proposed framework is rooted in the fundamental physical quantities governing radiation transport, allowing it to generalize to virtually any treatment geometry and planning objective. We developed two complementary sub-components: (1) An open-source implementation of a Linear Boltzmann Transport Equation (LBTE) solver based on the discrete ordinate method with multigroup energy discretization that provide the computational means to extract physics-informed features directly from DICOM data, specifically the RTPLAN file; (2) A physics-informed neural network architecture that learns to predict dose distributions from the LBTE-derived features with clinically accurate results and orders-of-magnitude faster computation than the traditional solution algorithms. The theoretical basis spans from Quantum Electrodynamics (Klein-Nishina cross-sections for Compton scattering) to Classical Charged Particle Physics (Bethe-Bloch stopping power for electron transport), to numerical transport methods, with all cross-sections, energy deposition mechanisms, and spatial discretization schemes obtained from first principles. The main novelty is the creation of novel input features - primarily the uncollided fluence Ψunc that include the total beam geometry, MLC aperture configurations, gantry angles, and fluence modulation patterns as computed via analytical ray-tracing similar to commercial solvers like Acuros XB. The physics-based representation of this feature set is what differen- tiates our approach from previous works: While previous methods would incorrectly predict dose deposition within the PTV regardless of the actual beam configuration, our frame- work will accurately predict the correct dose distribution for any arbitrary treatment plan, including unconventional geometries where dose is deposited outside the traditional target volumes. This capability has opened up unprecedented possibilities for inverse planning optimization using deep learning, since the network can perceive the physical characteristics of each beam and field shape. The neural network component utilizes a carefully-designed hybrid architecture com- bining a 3D U-Net for local feature extraction (e.g., tissue interfaces, density gradients, penumbral regions) with a Fourier Neural Operator (FNO) for capturing global spectral properties (e.g., beam geometry, scattering kernels, long-range energy transport). Spatial attention fusion adaptively combines local and global information on a voxel-by-voxel basis, while residual learning predicts corrections to the TERMA baseline, effectively learning the scattered dose and secondary electron transport contributions that comprise the computa- tionally expensive iterative component of transport solvers. The use of the softplus activation function allows for physics-consistent non-negative outputs while the use of gradient-based loss functions improves accuracy at charged-particle equilibrium break-downs near tissue interfaces. Validation of the forward dose-prediction model on 52 VMAT and 26 IMRT lung-cancer patients demonstrates that the framework meets clinical quality requirements on both deliv- ery modalities. For VMAT, the model achieves a mean gamma pass rate of 98.17% (5%/3 mm criteria, 10% dose threshold) with 92.3% of patients exceeding the 95% clinical acceptability threshold and a mean absolute error of 1.71 ± 0.17 Gy. For IMRT — the first evaluation of this framework on static-gantry delivery — the mean gamma pass rate is 89.59% with a mean absolute error of 0.84±0.18 Gy, demonstrating cross-modality generalisation: the same physics-based features enable accurate dose prediction for both continuous-arc and static- gantry deliveries without any modality-specific fine-tuning. The physics-informed nature of the approach enables the maximum dose to be deposited in the PTV while minimizing the dose to organs-at-risk, ultimately leading to improved therapeutic outcomes and reduced side effects associated with treatment. The large number of parameters (109 million) is suf- ficient to allow for the framework to achieve inference times suitable for real-time adaptive radiotherapy applications. The trained dose engine has been used as a ”frozen” or ”fixed” and ”differentiable” physics module in an end-to-end inverse treatment planning pipeline (Chapter 12), and beyond just predicting the dose to be delivered, the inverse planning network uses a new ”fluence-first” architecture to predict the fluence maps and MU for each field to be delivered based solely on the anatomy of the patient, completely eliminating the need for iterative op- timization using a conventional TPS. A novel structure-angle sheaf graph block is included in the inverse planning network to model the inter-beam dose interactions between fields as learned transport maps on a bipartite graph that includes signed attention. In addition, positive (support) and negative (risk) message channels allow the architecture to simulta- neously maximize target coverage and minimize OAR exposure by directionally diffusing sheaves. A bilevel curriculum training method is employed to train the network. In Phase 1 of this process, the network is anchored to supervised fluence targets. In Phase 2, the net- work is then trained on differentiable clinical physics including the loss functions associated with the constraints defined by the dose volume histograms (DVH-constraint hinge losses) and the Adjoint Clinical Transport Prior (ACTP) that maps voxel level clinical objectives to beamlet level fluence targets via the adjoint of the sparse dose kernel previously computed. Convex fluence projection with TV (total variation) and angular smoothness regularization is then applied to the fluence predictions made by the network to ensure that they can be delivered by the MLC. The key connection between forward prediction as outlined in Chapter 11 and inverse planning as outlined in Chapter 12 is the sparse dose transport kernel. Both the uncollided fluence and the TERMA can be computed using the same ray tracing operators derived from the Boltzmann equation used for feature extraction as described in Chapter 11. Thus the frozen dose prediction network in Chapter 11 will produce a 3D dose map directly from the predicted fluence maps in a single forward pass. The gradients from the clinical loss function will then travel backwards through the frozen dose network and the sparse kernels to reach the fluence predictor; thus completing the optimization loop without having to invoke a traditional treatment planning system (TPS). A validation study was completed on a subset of 50 VMAT lung cancer patients (AIRTP, 60 Gy/30 fr) demonstrates clinically competitive results with subsecond inference (∼323 ms per plan): gamma pass rate of 85.20±7.96% (5%/3 mm, 10% threshold), OAR sparing that matches or exceeds clinical reference plans (Lung V20 −0.5 pp, Cord D0.03cc +12.0 pp pass- rate improvement), and a characteristic coverage–protection trade-off where PTV V95%Rx pass rate is 14 pp lower than reference clinical plans but 4 out of 7 OAR objectives were achieved equal or higher rates. Most notably, the most clinically challenging case (a patient with bilateral pulmonary metastasis) had the lowest gamma score but produced a physically valid plan covering all of the target volumes appropriately protecting the organs at risk, which serves as direct evidence that the model learned the ”goal” of radiotherapy as opposed to simply learning the patterns in the ground truth plan. | en |
| dc.description.abstract | Ο καρκίνος αποτελεί μία από τις κυριότερες αιτίες θνησιμότητας παγκοσμίως, με τη θεραπευτική του αντιμετώπιση να αποτελεί ένα από τα πλέον σημαντικά ζητήματα της σύγχρονης ιατρικής. Περίπου οι μισοί εκ των ασθενών που διαγιγνώσκονται με κακοήθη νεοπλασία υποβάλλονται, αναλόγως της ιατρικής ένδειξης και της κλινικής απόφασης, σε ακτινοθεραπεία, συχνά συνδυαστικά με λοιπές θεραπευτικές προσεγγίσεις όπως η χημειοθεραπεία και η χειρουργική επέμβαση. Η αλληλεπίδραση της ιονίζουσας ακτινοβολίας με την ύλη, και ειδικότερα με τις ανατομικές δομές του ανθρώπινου ιστού, χαρακτηρίζεται από ιδιαίτερη φυσική πολυπλοκότητα. Η φυσική αλληλεπίδραση (ιονίζουσας ακτινοβολίας – ανθρώπινος ιστός) που λαμβάνει χώρα κατά την ακτινοθεραπεία περιγράφεται ρητώς από τις γραμμικές διαφορικές εξισώσεις του Boltzmann (LBTE). Καθώς ο αλγόριθμος που μελετάται και μοντελοποιείται είναι ο Acuros XB οπού αποτελεί την τελευταία λέξη της κλινική πράξης, παρέχοντας ακριβή υπολογισμό της κατανομής δόσης σε ετερογενή μέσα μέσω ντετερμινιστικής επίλυσης των εξισώσεων (LBTE), προσομοιώνοντας τη μεταφορά πρωτογενών και σκεδαζόμενων φωτονίων και τη συμβολή των παραγόμενων δευτερογενών ηλεκτρονίων στην τελική εναπόθεση ενέργειας. Η μελέτη εστιάζει στην ακτινοθεραπεία του καρκίνου του πνεύμονα, ενός νεοπλάσματος που παρουσιάζει ιδιαίτερες δοσιμετρικές και κινηματικές προκλήσεις λόγω της έντονης ετερογένειας των ιστών της θωρακικής περιοχής και της αναπνευστικής κίνησης. Η ανάγκη για ταχεία και αξιόπιστη εξαγωγή κατανομών δόσης είναι ιδιαίτερα κρίσιμη στον πνεύμονα, όπου η αναπνευστική κίνηση και οι ενδοσυνεδριακές ή διασυνεδριακές ανατομικές μεταβολές καθιστούν αναγκαίες πιο ευέλικτες και προσαρμοστικές στρατηγικές θεραπείας, όπως η Adaptive Radiation Therapy. Πέραν του υπολογιστικού κόστους και του χρόνου εξαγωγής πλάνου, κεντρικές ακτινοθεραπευτικές προκλήσεις αποτελούν η μεγιστοποίηση της δόσης εντός του όγκου-στόχου (περιοχής ενδιαφέροντος της καρκινικής περιοχής), ώστε να επιτυγχάνονται οι ιατρικώς προτεινόμενες χορηγούμενες ακτινοθεραπευτικές δόσεις, με ταυτόχρονη προστασία των παρακείμενων ακτινοευαίσθητων οργάνων (OARs) σεβόμενοι τα δοσιμετρικά ακτινοπροστατευτικά όρια, διασφαλίζοντας τη βέλτιστη ισορροπία μεταξύ θεραπευτικής αποτελεσματικότητας και αποτροπής των μη αναστρέψιμων βλαβών σε OARs από την ακτινοβολία. Στο πλαίσιο αυτής της εργασίας, παρουσιάζονται τεχνικές deep learning που επιτυγχάνουν τον ταχύ υπολογισμό κατανομών δόσης και την παραγωγή αποδοτικών ακτινοθεραπευτικών πλάνων. Αναλύεται αρχικά το ευθύ πρόβλημα δηλαδή η πρόβλεψη της τρισδιάστατης κατανομής απορροφούμενης δόσης για δεδομένη ανατομική γεωμετρία, πυκνότητα ιστών και ακτινοθεραπευτικού πλάνου και εν συνεχεία το αντίστροφο πρόβλημα η βελτιστοποίηση των παραμέτρων του πλάνου προς επίτευξη επιθυμητής κατανομής δόσης. Οι προτεινόμενες μεθοδολογίες συνιστούν πρωτότυπες ερευνητικές συμβολές που, εξ όσων προκύπτει από τη διεθνή βιβλιογραφία, δεν έχουν παρουσιαστεί αντίστοιχα στο ερευνητικό πεδίο, και αποσκοπούν στην αντιμετώπιση θεμελιωδών προβλημάτων της υπολογιστικής ακτινοφυσικής όπως τον υπολογισμό δόσης σε χρόνο συμβατό με κλινική ροή εργασίας, την αυτοματοποιημένη και γρήγορη βελτιστοποίηση πλάνων χωρίς επαναληπτική χειροκίνητη παρέμβαση, και τη δυνατότητα εφαρμογής πρωτοκόλλων προσαρμοστικής ακτινοθεραπείας σε ανατομικές περιοχές με σημαντική ενδο-κλασματική κινητικότητα | el |
| dc.identifier.uri | https://apothesis.hmu.gr/handle/123456789/11809 | |
| dc.language.iso | en | |
| dc.publisher | ΕΛΜΕΠΑ, Πολυτεχνική Σχολή, Τμήμα Ηλεκτρολόγων Μηχανικών και Μηχανικών Υπολογιστών | |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Radiotherapy | |
| dc.subject | Deep learning | |
| dc.subject | Lung cancer | |
| dc.subject | Machine learning | |
| dc.subject | Dose prediction | |
| dc.subject | Real-time optimization | |
| dc.subject | Ακτινοθεραπεία | |
| dc.subject | Βαθιά μάθηση | |
| dc.subject | Καρκίνος του πνεύμονα | |
| dc.subject | Μηχανική μάθηση | |
| dc.subject | Πρόβλεψη δόσης | |
| dc.subject | Βελτιστοποίηση σε πραγματικό χρόνο | |
| dc.title | Machine learning techniques for accelerating Monte Carlo simulations in radiotherapy and optimizing treatment planning | en |
| dc.title | Χρήση τεχνικών μηχανικής μάθησης για την επιτάχυνση των προσομοιώσεων Monte Carlo στην ακτινοθεραπεία και τη βελτιστοποίηση του σχεδιασμού θεραπεία | el |
| dc.type | Πτυχιακή Εργασία | |
| heal.academicPublisherID | Ελληνικό Μεσογειακό Πανεπιστήμιο |
Αρχεία
Πρωτότυπος φάκελος/πακέτο
1 - 1 of 1
Φόρτωση...
- Ονομα:
- SalonikiouKonstantinos2026.pdf
- Μέγεθος:
- 18.07 MB
- Μορφότυπο:
- Adobe Portable Document Format
Φάκελος/Πακέτο αδειών
1 - 1 of 1
Δεν υπάρχει διαθέσιμη μικρογραφία
- Ονομα:
- license.txt
- Μέγεθος:
- 2.17 KB
- Μορφότυπο:
- Item-specific license agreed upon to submission
- Περιγραφή: